BT2 floor standing commercial electric boiler

 Commercial Electric  Boilers
NO. Name Model Specification
1 Function   Closed Type Single System Heating Only Installation Instruction
Dual System with Heating and hot water
2 Picture                                        
3 Rated Power(KW) heating 15 20 25 30 40 50
shower 15 15 15 25 25 25
4 Rated Current(A)   23 30 38 46 61 76
5 The leakage switch(A)   32-4P 40-4P 50-4P 63-4P 80-4P 100-4P
6 Air Switch(A)   >32 >40 >40 >60 >63 >80
7 Copper Core(M2)   >4 >6 >6 >10 >10 >16
8 Rated Voltage (V)   380 380 380 380 380 380
9 Frequency(HZ)    50 50 50 50 50 50
10 Inlet & Outlet Connection(IN)   G1 G1 G1 G1 G1 G1
11 Backwater Inlet Connection(IN)  heating G1 G1 G1 G1 G1 G1
shower G1/2 G1/2 G1/2 G1/2 G1/2 G1/2
12 Pressure(MPA) heating 0.06-0.3 0.06-0.3 0.06-0.3 0.06-0.3 0.06-0.3 0.06-0.3
shower 0.2-0.6 0.2-0.6 0.2-0.6 0.2-0.6 0.2-0.6 0.2-0.6
13 Range of heating water temp. () heating 30-85 30-85 30-85 30-85 30-85 30-85
14 Range of bath water temp. () shower 30-55 30-55 30-55 30-55 30-55 30-55
15 Area ()   100-150 150-200 200-250 250-300 350-400 450-500
16 First Class Anti-freezing function activate temp. ()   8 8 8 8 8 8
17 First Class Anti-freezing function stop temp .()   15 15 15 15 15 15
18 Product Size (mm)    480*600*980 480*600*1080
19 Net Weight  (mm)   78 83
20 Gross Weight   (mm)   100 105
21 Single Packing Size (L/W/H) (cm)     73x62x127 73x62x137
22 Outside Package Size (L/W/H) (mm)    ****** ******
23 Volume CBM)   0.6 0.62
24 FLQ(units/20GP)                                                           ****** ******
25 FLQ (units/40HQ)        ****** ******

Power saving core accessories of the commercial electric boiler
Using space 3D labyrinth rapid heating technology, the temperature is quickly heated to the set temperature, and the constant temperature is saved. In addition, we also use the controllable silica gel variable temperature technology to keep every part of the furnace running in a state of power saving, to ensure that the power consumption during the use of the furnace is kept at a minimum.
1. Three-dimensional labyrinth heating body
The water and electricity separation technology uses the principle of metal water and electricity separation, that is, water walking water path, electric walking circuit, water and electricity without any contact from the source to prevent leakage and leakage, 100% to ensure the safety of users.
2. Controllable variable temperature technology
Constant temperature control wide voltage operation, even if the working voltage is unstable, the furnace can operate normally, automatically adjust the power size, change the constant temperature, save energy and save electricity.

Call +86 (0)13825579110 to Get More Information