BT1 floor standing commercial electric heating boiler

 Commercial Electric  Boilers
NO.NameModelSpecification
1Function Closed Type Single System Heating Only Installation Instruction
Dual System with Heating and hot water
2Picture                                      
3Rated Power(KW)heating152025304050
shower151515252525
4Rated Current(A) 233038466176
5The leakage switch(A) 32-4P40-4P50-4P63-4P80-4P100-4P
6Air Switch(A) >32>40>40>60>63>80
7Copper Core(M2) >4>6>6>10>10>16
8Rated Voltage (V) 380380380380380380
9Frequency(HZ)  505050505050
10Inlet & Outlet Connection(IN) G1G1G1G1G1G1
11Backwater Inlet Connection(IN) heatingG1G1G1G1G1G1
showerG1/2G1/2G1/2G1/2G1/2G1/2
12Pressure(MPA)heating0.06-0.30.06-0.30.06-0.30.06-0.30.06-0.30.06-0.3
shower0.2-0.60.2-0.60.2-0.60.2-0.60.2-0.60.2-0.6
13Range of heating water temp. ()heating30-8530-8530-8530-8530-8530-85
14Range of bath water temp. ()shower30-5530-5530-5530-5530-5530-55
15Area () 100-150150-200200-250250-300350-400450-500
16First Class Anti-freezing function activate temp. () 888888
17First Class Anti-freezing function stop temp .() 151515151515
18Product Size (mm)  480*600*980480*600*1080
19Net Weight  (mm) 7883
20Gross Weight   (mm) 100105
21Single Packing Size (L/W/H) (cm)   73x62x12773x62x137
22Outside Package Size (L/W/H) (mm)  ************
23Volume CBM) 0.60.62
24FLQ(units/20GP)                                                         ************
25FLQ (units/40HQ)      ************


Power saving core accessories of the commercial electric heating boiler
Using space 3D labyrinth rapid heating technology, the temperature is quickly heated to the set temperature, and the constant temperature is saved. In addition, we also use the controllable silica gel variable temperature technology to keep every part of the furnace running in a state of power saving, to ensure that the power consumption during the use of the furnace is kept at a minimum.
1. Three-dimensional labyrinth heating body
The water and electricity separation technology uses the principle of metal water and electricity separation, that is, water walking water path, electric walking circuit, water and electricity without any contact from the source to prevent leakage and leakage, 100% to ensure the safety of users.
2. Controllable variable temperature technology
Constant temperature control wide voltage operation, even if the working voltage is unstable, the furnace can operate normally, automatically adjust the power size, change the constant temperature, save energy and save electricity.